                                SOFT990 V4.46
     
                CONTROL SOFTWARE FOR YAESU TRANSCEIVERS
               
                                 (C) 1997  F6DEX
                                 ---------------
               
        0. Distribution
        ---------------
               
        SOFT990 is distributed as free. Its use is free also. 
     
        Soft990    is   copyrighted   by   Laurent   Labourie    F6DEX
     (IDDN.FR.001.400009.00.R.P.1997.000.31400).
        
        Permission  for any commercial use and distribution is expres-
     sly denied. 
     
        A  report on its use and any bugs,  comments,  or  suggestions 
     would  be very appreciated on a qsl via bureau or  via e-mail  at
     101713.3444@compuserve.com.
     
        To download SOFT990 and update :
     
        On CompuServe : GO HAMNET (Equipment/Antennas)
        
        On Internet   : http://ourworld.compuserve.com/homepages/f6dex
               
        Thanks  to Christophe DENIS for his help to test the soft with
     FT-840,  Bill WD8ARZ and Joe K1JN for help to test the FT-1000MP,
     Barry AE4RG for help to test the FT-920,  Marc Andre VE2JFK & Ri-
     cardo  PY6SB for help to test the FT-890 and Hans DL5RAZ for  his
     help to solve a timing bug with some interfaces.
     
        A  Windows 95/NT version called FT-Manager is now  distributed
     as shareware at : http://ourworld.compuserve.com/homepages/f6dex.
     
        You may also read the FT-MAN.TXT file for more information.
     
        1. SOFT990 overview
        -------------------
               
        SOFT990  helps  you to command a YAESU transceiver  FT-990  or
     FT-890/FT-900/FT-840/FT-920/FT-1000MP/FT-1000D  with  a  personal
     computer.
     
        Below are some of the features of SOFT990 :
               
        - large display of the transmit and receive frequency
        - digital s-meter with memory
        - signal vs time analysis
        - easy and quick operation in split and qsx, reverse CW
        - dualwatch capability
        - quick memories
        - window for tnc operation (if connected)
        - graphic band scope to check activity on a band
        - channel information
        - automatic mode and filter switching
        - simulate two transceivers (like a quick memory for all para-
     meters)
        - functions in  relation with a dx-cluster even if "DISCONNEC-
     TED" (SWL) and DXCC information
        - possibility to store the 90 (99/32) memories on hard disk
        - data base for BCL frequencies - scanning...
        - mini log-book function compatible with Log-EQF files
                   
        2. System requirements
        ----------------------
               
        - "old"  IBM  PC or compatible (tested with 80286 and DOS 5.0)
        - EGA/VGA monitor 25*80 lines (text mode)
        - 1 serial port for radio interface
        - 1 serial port for Terminal Node Controller (optional)
        - CAT system interface (except FT-920 FT-1000MP)
         
        Note :
     
        - early  FT-990 or FT-890 firmware (prior to rev.   1.3)  does
     not  run with SOFT990 (except BCL module with limited functions :
     select "0" as parameter for "transceiver" (SETUP)
     
        - the  FT-1000 (to distinguish from the FT-1000D) does not run
     with  SOFT990 (except BCL module with limited functions :  select
     "0" as parameter for "transceiver" (SETUP)
     
        -  the "0"  selection for "yaesu transceiver"  should run with
     all Yaesu transceivers but with limited functions (BCL only), 
     
        - with FT-840 the clarifier is not supported.
     
        - with FT-920 : BCL and BAND SCOPE are running only with VFO A
     selected,  scanning  functions (keys 2,4,6,8) are not  supported,
     scanning function with +/- keys will mute the transceiver, REVER-
     SE  CW (CW LSB) can't be memorised in a Soft Quick Memory or in a
     file,
     
        - with FT-1000MP and FT-1000D : BCL and BAND SCOPE are running
     with  VFO A selected (the software equalize main and sub-receiver
     before  scanning  to allow tuning around your  current  frequency
     with sub-receiver), scanning by step of 10/100 hz with keys 4 & 6
     is not working,
     
        - COM3 or COM4 avalaible for selection with following restric-
     tion  :  When  COM3 (or COM4) is selected the software will  swap
     adress  of COM3 (or COM4) with adress of COM1 (or COM2) ;  selec-
     tion of COM1 and COM3 (or COM2 and COM4) at once is not possible.
     The  initial  setting of serial port is restored when ending  the
     program.  This  feature is absolutely not compatible with Windows
     (exit Windows) and with some PC (for COM3 and/or COM4),
     
        -  the bests results are with a old PC (which speed match  the
     slow rate of the FIF232 interface) and with very "basic" settings
     in CONFIG.SYS and AUTOEXEC.BAT.
     
        - if  your  interface or your transceiver is off  the  program
     freezes : sorry for this drawback ; it would be actually delicate
     to  solve the problem while keeping a compatibility with all com-
     puters and interfaces..
     
               
        3. Installation
        ---------------
               
        - create a directory on your hard drive called C:\SOFT990
        - copy the file SOFT990.zip into the directory - you just made
     and unzip it. You should see the following 30 files :
               
                          . SOFT990.EXE
                          . SETUP.EXE
                          . TERMINAL.EXE
                          . LOGBOOK.EXE
                          . BRUN45.EXE
                          . ANALYSE.EXE
                          . PANEL.EXE
                          . FUNCTION.EXE
                          . SOFT990.CNF
                          . SOFT990.DAT
                          . BAND.DAT
                          . INFO.DAT
                          . README.TXT
                          . LISEZMOI.TXT
                          . RIG.DAT
                          . DXSPOT.DAT
                          . PREFIX.DAT
                          . BEACONHF.MEM        
                          . BEACON28.MEM
                          . SOFT990.PIF
                          . BCL.EXE
                          . ENGLISH.BCL
                          . FRENCH.BCL
                          . GERMAN.BCL
                          . SPANISH.BCL
                          . PRINTER.DAT
                          . BCL.BIN     
                          . MS-DOS.PIF
                          . F6DEX HOMEPAGE.URL
                          . FT-MAN.TXT
               
        -   run  SETUP.EXE and enter the parameters for  communication
     between the PC and interfaces and settings in this order :
               
                          . serial port for TRX (1 or 2)
                          . serial  port  for TNC (1 or 2 or 0 if  not
     used)
                          . speed rate (baud) for TNC (if used)
                          . parity for TNC (if used)
                          . data bits for TNC (if used)
                          . stop bits for TNC (if used)
                          . your latitude (>O if north)
                          . your longitude (>0 if east)
                          . hours to add to clock for UTC time
                          . code for transceiver
                            (1 for FT-990 ROM 1.3, 2 for FT1000MP
                             3 for FT-840, 4 for FT-890, 5 for FT-900
                             6 for FT-920, 7 for FT-1000D,
                             0 for other Yaesu transceivers)
                          . preference filter for SSB
                          . preference filter for CW
                          . CW Pitch (400 - 700 hz) for CW reverse
                          . preference filter for AM
                            (0=2.4K 1=2.0K 2=500K 3=250K ou CWN
                             5=6.0K)
                          . choice for colors from 0 to 5 (0 for LCD)
                          . choice for sound (1=ON 0=OFF)
                          . speed of your PC (1-3000) : (1 for a
                            80286/12 and about 3500 for a P120)
     
      
        SOFT990  doesn't  run correctly from a DOS session of  WINDOWS
     95/NT  then  if  WINDOWS 95 is in use create a  shortcut  to  run
     SOFT990.EXE in DOS real mode : with a rigth click select "proper-
     ties"  then   "DOS MODE"  in "advanced parameters"  for "program"
     (this shortcut is given in the zip file).
     
        Disable any resident program as screen blanker...
     
        To set the speed parameter you can run the software then run a
     scanning with [+] or [-] ; increase the value until the TRX stops
     scanning immediately after pressing a key.  Also you can increase
     the value if the software locks up.
         
     
        4. Operation
        ------------
     
        IMPORTANT :  Switch on your transceiver Yaesu and your TNC (if
     used).  Then  if WINDOWS 95 is in use re-boot your PC into MS-DOS
     real mode and run SOFT990 from the directory where SOFT990 is in-
     stalled (C:\SOFT990) as follow :
     
        C:\SOFT990> SOFT990 [path\logfile] 
     
        It  is also possible to enter parameters in the shortcut  pro-
     perties and to make a double clic on SOFT990 or MS-DOS. 
     
        See 4.3 for the optional parameters [path\logfile]
     
        4.1 Normal operation (monitoring screen)
        ----------------------------------------
     
        The  communication between PC and TRX is relatively slow (4800
     bauds) so there is a delay between "action" and "effect"
     
        Operation  is easy.  The ten F-KEY (F1 to F10) are assigned to
     the following functions :
                        
        F1(HELP)   : displays "help screen" (any key to quit)
          
        F2(FREQ)   : sets frequency
     
                . (RECEIVE) for transceiver operation
                . (TRANSMIT) transmit frequency (split)
                . (QSX) offset for transmit frequency up/dn khz
          
        F3(BAND)   : band selector
          
        F4(MODE)   :  sets  a mode or "AUTO"  for "soft-switching"  of
     mode as per BAND.DAT file
          
        F5(MEM)    : submenu for memories : 
     
                . (CHECK) to display 12 channels
                . (CHECK ALL) to display all channels
                . (INFO) to enter a label or info
                . (SCANNING) to scan memories by software
                . (HIDE/UNHIDE) to hide/unhide memories
                . (SKIP/INCLUDE) to skip/include memories in scanning
                . (SAVE/UPLOAD) to save/create files of memories
          
        F6(TNC)    : to open tnc mode or or a submenu 
     
                . (MONITOR) to display packet activity
                . (TERMINAL) to run terminal module (see 4.2)
                . (AUTO-DX) automatic qsy for incoming dx-spot
                . (DX-FILTER) to display dx-spot only
          
        F7(SCOPE)  : band scope mode (see 4.5)
     
        F8(MENU)   :  to open a menu for other functions (dx-spot data
     base, settings...)
     
        F9(METER)  :  submenu to :  reset maximum deviation of s-meter
     or toggle for V/S-db readout
          
        F10(EXIT)  : to quit SOFT990 and return to DOS
               
        Esc        : after a qsy to restore last frequency in use
     
        Tab        : Pop up menu to set frequencies modes filters... -
     this function stop the monitoring - Esc to quit
     
        Alt-D      : switch TRX on last dx-spot frequency
        X          : to search DXCC info for a given callsign
        Alt-O      : switch to DOS (return with exit)
        ALT-L      : Opens the Log Book
        ALT-B      : Run BCL module
        G          : Signal analysis
        N          : toggles  operation  between trx num  1  and num 2
        D          : dualwatch function
        P          : toggle  to display info from VFO+Channel or Quick
     memories
        H          : Help  window for all keyboard shortcuts (not lis-
     ted here)
        V          : To store a transceiver's memory with info
     
        Arrow key  : (left and right) to select DXCC country when dis-
     played in the dx-spot box.
     
                   : (up and down) to select a canal
     
        For  all menus the editing keys INSER DELETE AND BACKSPACE are
     activated.
     
     
        Special features :
        ------------------
     
        HOW TO QSY ? :
     
        It  is  possible to enter a frequency with F2  ;  The  numeric
     key-pad is also used to scan as follow :
               
                  8           : up 100 khz (*)
                  2           : down 100 khz (*)
                  4           : down 10 hz (or 100 hz / FAST) (*)
                  6           : up 10 hz (or 100 hz / FAST) (*)
                  +           : auto-scan up
                  -           : auto-scan down
     
     (*) except FT-920
     
        To  stop auto-scan press any key except function key and 8 2 4
     6.
     
        The F3 key allows to change the band.  Frequency, mode,  band-
     width  and  antenna tuner settings are being maintained for  each
     band.
     
     
        DUALWATCH :
     
        The DUALWATCH feature is activated with the key [D] - then the
     software toggles from VFO A to VFO B each 8s - press again [D] or
     key down to stop,
            
     
        AUTO MODE :
     
        When  this function is activated (AUTO is displayed) the soft-
     ware  sets  the mode as per BAND.DAT file (see 6.3 to alter  this
     file if necessary) :
     
        - in "mem mode" (on TRX) auto-mode is off (MANUAL),
               
        - when "qsy" for the time in a new mode : filter by default is
     selected,
               
        - in auto-mode :  around the limit between two modes,  mode is
     not stable : set a mode manually (press F4),
     
          
        CHANNEL INFORMATION :
     
        It  is possible to  enter literal information for the  channel
     in use : press  VFO/M on TRX then F4 (INFO) or press [V] to enter
     a memory and info simultaneously
     
          
        QUICK MEMORIES (QMB) :
     
        It  is  possible to store up to 4 frequencies as  quick  memo-
     ries (sequential) :
     
        . Press  Ctrl+ENTER  to store a frequency (+ mode  filter  and
     info if avalable as DX-cluster/BCL)
        . Press BKSP to recall memory number 1
        . Press P to display the content of the quick memories
     
     
        SIGNAL VS TIME ANALYSIS
     
        This  function allows to display signal vs time.  Press [G] to
     run analysis. This feature slow down the monitoring.
     
        Then press :
     
        - [Alt]+[G] to speed up analysis (but monitoring will be stop-
     ped)
     
        - [G] to resume normal analysis and [G] again to stop analysis
     
     
        CW REVERSE (FT-990 FT-890 FT-840 FT-900)
     
        This  function  allows  to listen CW in LSB mode  using  split
     mode.  It  is necessary to enter the value of CW Pitch via  SETUP
     (400 - 700 hz).
     
        To use this function : 
     
                . adjust  the operating frequency (VFO) for the selec-
     ted pitch
                . press [Alt]+[W]
                . adjust IF Shift (1/4 clockwise) to center the signal
     (only if a narrow filter is in use)
                . press [W] to restablish normal CW mode.
     
        It is possible to offset the transmit frequency with [Q]SX.
     
        It  is necessary to reset CW-REVERSE before to change mode  or
     frequency because the transceiver is switched in split mode.
     
     
        QUICK SPLIT
     
        A Quick split function is provided using F2(FREQ).
     
        The feature allows to set :
     
        - transmit frequency and split mode (with same mode as receive
     frequency)
        - offset (QSX) for transmit frequency in Khz
     
     
        4.2 TNC operation (terminal mode)
        ---------------------------------
     
        The KEY are assigned to the following functions :
                  
        F2(AUTODX) : to  go back to monitoring (main module) and auto-
     matic qsy in relation with the last dx-cluster spot
     
        F3(CMD:)   : to send a command to tnc
          
        F7(DNLOAD) : to  download data from tnc to hard disk (tnc.out)
     - press again F7(DN-OFF) to stop
     
        F4(SPOT)   : to send a dx-spot : the soft prompt D FREQ
             
        F8(SND-OF) : to switch "sound" off - press again F8(SND-ON) to
     switch on
     
        F9(FILTER) : toggle to set on/off the dx-spot filtering.  When
     ON  (DX-FILTER is displayed in TNC mode) the monitoring mode will
     only  display  dx-spot.  This  feature is avalaible even  if  not
     connected.
     
        F10(EXIT)  : to quit SOFT990 and return to DOS
               
        F6(YAESU)  : in  "tnc"  mode  :   quit TNC and update TRX  but
     allow monitoring of tnc activity until a new action
          
        Esc        : same function as F6
     
        Tab        : to set <on> or <off> the editing function
     
        PgUp/PgDn  : to display the 90 lines from the buffer
     
        Notes :
     
        - on TNC set AUTOLF ON
     
        - in  auto-dx  mode the TRX qsy on the frequency of  the  last
     dx-cluster spot ;  operate to stop this function (PTT, LOCK, ENT)
     or use F-keys and "space bar"
     
     
        4.3 Log-book module
        -------------------
     
        4.3.1 Features
        --------------
     
        SOFT990 is not a logging software ;  the purpose of this func-
     tion is :
     
        - to add qso on a trafic-database
        - to view and edit the trafic-database
     
        Additional features are provided :
     
        - search for fields
        - "quick" print of the Log
        - text file export utility (CSV format)
     
        These  functions are limited :  it is not possible to cancel a
     qso prevously recorded but the soft read the Log-Eqf file format.
     Log-Eqf  is  a shareware program copyrighted by  N3EQF  (download
     at : http://www.itis.net/eqf). Log-Eqf is necessary to manage the
     trafic data-base (QSL DXCC...).
     
        The  software  is  able  to  write data's  into  a  text  file
     (Log.txt) using the CSV format.
     
        The Logbook module is able to restore (from main module) :
     
                . Callsign (dx-spot)
                . DXCC info
                . Date
                . Time
                . Frequency
                . Mode
                . RS(T) from rx 
                . QSL manager (dx-spot if a "via" or "qsl" is present)
                . Info (dx-spot)
     
        4.3.2 Operation
        ---------------
     
        To open the Log-book run SOFT990 as follow :
     
                . from DOS > SOFT990 [path\log file]
     
        where  path\log file is the path and the file name of the  Log
     file.
     
        The default are as follow :
     
        - current directory
        - SOFT990.LOG as Log file
        - .LOG as extension 
     
        Example :
     
        C:\SOFT990 > SOFT990 C:\LOG-EQF\F6DEX.LOG
     
        It  is possible to call directly the logbook from DOS with the
     same parameters : LOGBOOK [path\log file]
     
        Note  that the soft doesn't make any backup of your log  file.
     So it is usefull to make a backup in a batch file as follow :
     
        CD C:\SOFT990
        COPY C:\LOG-EQF\XXXXX.LOG XXXXX.BAK
        SOFT990 C:\LOG-EQF\XXXXX
     
        where XXXXX.log is your log file.
     
        When  logging  the soft stop communication betwwen PC and  TRX
     except when you press F5.
     
        Then  when running SOFT990 it is possible to open the  logbook
     with the menu (F8) ,the shortcut Alt-L or the key Home.
     
        4.3.3 Keys
        ----------
     
        Use the arrow keys or "Tab" to move from one field to another.
     
        The KEY are assigned to the following functions :
                  
        F1 (HELP)   : display help-screen
          
        F2 (SAVE)   : save the new entry
          
        F3 (TIME)   : sets current date and time
          
        F4 (SPOT)   : sets "Callsign"  "Country" "Mgr" and "Info" with
     the current dx-spot info,
     
        F5(FREQ)    : sets "Frequency" "Mode" and "RS(T)"
        
        F6(YAESU)   : return to SOFT990
          
        F7(FIND)   : callsign  search  function  > fill in  the  field
     "CALLSIGN" with the required characters and press F7
     
                        Example : 
     
                        Callsign => dex
                        (F7)    : will search for "dex" in a callsign.
     
        F8 (MENU)  : opens the menu for :
     
                        . "quick print of the Log
                        . text file export utility (CSV format)
                        . Logbook selection
                        . DOS mode
                        . multi  fields  search  function  (to  repeat
     press Alt+R)
          
        F9(CLEAR)  : clear all fields
           
        F10(EXIT)  : Exit SOFT990 and return to DOS.
     
        Esc        : in NEW ENTRY mode = F6
     
                   : in VIEW mode return to NEW ENTRY mode
     
                   : or cancel the current request
     
        Home/End   : to scroll back/down from the beginning/end of the
     Log
     
        PgUp/PgDn  : to scroll the the Log
     
        Ctrl+PgUp  : activate the VIEW mode for a qso displayed in
        Ctrl+PgDn  : the upper window - to save any change press F2.
     
        See at 6.11 the structure of the log file.
                  
        Note :
     
                - the date format is ONLY dd-Mmm-yy (Mmm > Jan Feb Mar
     Apr  May  Jun Jul Aug Sep Oct Nov Dec).  The time format is  only
     hh:mm
     
                -  Multi  fields search function  F8(SEARCH...)   : to
     use  this  function clear fields with F9 then fill in the  search
     field with the required characters and press F8
     
                        Example : 
     
                        (F9)
                        Callsign => dex
                        Date     => 95
                        (F8..)   : will search for "dex" in a callsign
     of a qso made in 1995.
     
                -  To delete a qso :  fill in the qsl's field with '*'
     or blank the callsign's field. Then use the Log-EQF's PURGE func-
     tion to purge the file.
     
     
        4.4 Broadcast listening module
        ------------------------------
     
        This module allow to listen BCL station from a file (*.BCL).
     
        Open  the menu of SOFT990 to run this module or use the short-
     cut Alt-B.
     
        The KEY are assigned to the following functions :
                  
        F1 (HELP)  : help screen
          
        F2 (SET-R) : to set receive frequency
          
        F3 (EDIT)  : to  edit or cut the selection with possibility to
     paste with the last deleted entry or to add a new entry.
     
        WARNING    :  the software doesn't save any change on the text
     file (*.bcl) unless to use the SAVE FILE subfunction. 
          
        F4 (PANEL) : Pop up menu to set frequencies modes filters... -
     this function stop the monitoring - Esc to quit
     
        F5(SCAN)    : to set parameters for scanning and to start scan
     (to  scann  all the file select a "FROM TIME"  greater  than  "TO
     TIME"  or use the toggle F3). During scanning the following func-
     tions are available :
     
                . F5 to stop scanning
                . <Space> for a pause - <Space> again to resume
                . up/down arrows keys : to change direction
        
        F6(YAESU)   : return to main module
          
        F7(SORT)    : to sort informations by frequency mode ...
     
        F8(FILE)    : to save or upload a file of datas
           
        F10(EXIT)   : to quit and return to DOS
     
        Esc         : Stops scanning or back to last selection
     
        Home/End    : to go at the beginning/end of the list
     
        PgUp/PgDn   : to scroll the list
     
        Enter       : to upload a frequency
     
        Space bar  : to skip a selection (except scanning)
     
        Tab         : Pop  up menu to set frequencies modes filters...
     - this function stop the monitoring - Esc to quit
     
        V           : To transfer a frequency to a memory channel with
     info  - Warning :  the software add ONE to the channel number and
     resets the transceiver to the last VFO used in monitoring mode
     
        Arrow keys : To skip a selection - when scanning : changes di-
     rection of scanning.
     
        See 6.9 for the file format.
     
        4.5 Band scope
        --------------
     
        This  function simulate a spectrum analyser.  A graphic tuning
     is possible.
     
        Parameters :
     
        CENTER FREQUENCY        : center frequency in Mhz
        HALF WIDTH              : half width of spectrum in Khz
        NOISE FLOOR             : in  s-unit ;  this parameter is used
     only  for the "text mode"  spectrum displayed when coming back to
     main program
                
        ACCURACY                : allows  to set accuracy of  spectrum
     (1=low  8=high) - this parameter sets also the duration of  spec-
     trum analysis. When 0 is selected the software doesn't scan : the
     spectrum depends only on the current frequency s-meter reading.
     
        MODE/FILTER             :  the software select the appropriate
     filter  for scanning when A (AUTO) is selected.  If the result is
     not  satisfactory it is possible to keep the current selection on
     TRX  with C (CURRENT) as parameter but in this case a fast AGC is
     necessary.
     
        The duration of scan depends on band activity.
     
        A  graphic tuning is possible with help of the left and  right
     arrow keys. They allow to move the cursor : press any key to stop
     and  tune  your transceiver on the new frequency ;  press Esc  to
     cancel the QSY.
     
        5. Press this ... to ... or to run ...
        --------------------------------------
  
  Ŀ
  Key :  MONITORING      TNC         BCL       LOGBOOK    BAND SCOP 
  Ĵ
  F1    help screen help screen help screen help screen help screen 
  F2    enter qrg   auto dx modeenter rx qrgsave entry  enter rx qrg
  F3    band switch command:    edit entry  set time    toggle trace
  F4    mode        dx spot infoCAT control set callsigntoggle mode 
  F5    memories                scan file   set qrg/modescan again  
  F6    run tnc     monitoring  monitoring  monitoring  monitoring  
  F7    band scope  upload file sort a file find a call zoom        
  F8    submenu     sound on/offopen/save   submenu     set param.  
  F9    s-meter     DX filter   DOS         clear entry DOS         
  F10   exit soft   exit soft   exit soft   exit soft   exit soft   
  Esc   last qrg    monitoring  last qrg    monitoring  last qrg    
  1     -250 hz                 -250 hz                 -250 hz     
  2     -100 khz                -100 khz                -100 khz    
  3     +250 hz                 +250 hz                 +250 hz     
  4     -10 hz                  -10 hz                  -10 hz      
  5                                                                 
  6     +10 hz                  +10 hz                  +10 hz      
  7     -1 khz                  -1 khz                  -1 khz      
  8     +100 khz                +100 khz                +100 khz    
  9     +1 khz                  +1 khz                  +1 khz      
  0                                                                 
  +     scan up                 scan up                 scan up     
  -     scan dn                 scan dn                 scan dn     
  =     A=B                     A=B                     A=B         
  BkSp  recall QM               recall QM               clear plot  
  Home  Logbook                 top of file top of file             
  Tab   CAT control type ahead  CAT control                         
  PgUp              scroll up   scroll up   scroll up               
  PgDn              scroll dn   scroll dn   scroll dn               
  End                           end of file end of file             
  Up    channel +               entry up    field up                
  Dn    channel -               entry down  field down              
  Left  see dx info                                                 
  Right see dx info                                                 
  A     vfo A                   vfo A                   vfo A       
  B     vfo B                   vfo B                   vfo B       
  C     channel op.                                                 
  D     dualwatch                                                   
  E     clear offset                                                
  F     FM                      FM                      FM          
  G     signal anal.                                                
  H     help                                                        
  I     swit. filter            swit. filter            swit. filter
  J                                                                 
  K     key down                                                    
  L     LSB                     LSB                     LSB         
  M     AM                      AM                      AM          
  N     toggle trx                                                  
  O     offset on/of                                                
  P     display QM              display QM                          
  Q     QSX                                                         
  R     start tuner                                                 
  S     split                   split                   split       
  T     tuner on/off            tuner on/off            tuner on/off
  U     USB                     USB                     USB         
  V     VFO > M                 VFO > M                             
  W     CW                      CW                      CW          
  X     prefix info                                                 
  Y     RTTY (PKT)              RTTY (PKT)              RTTY (PKT)  
  Z                                                                 
  Alt+B run BCL                                                     
  Alt+D last DX                                                     
  Alt+L logbook                                         logbook     
  Alt+O DOS                                                         
  Alt+W reverse CW                                                  
  Ent                           listen entry            smooth plot 
  Ct+Ententer QM                enter QM                            
  Ct+PgU                                    edit up                 
  Ct+Pgd                                    edit down               
  
     
     Note : in  order  to  solve any incompatiblity problem  with  the
     function keys (F1 to F10) the following shortcuts have been added
     (monitoring bcl and band scope only) :
     
     Alt+1 = F1
     Alt+2 = F2
     ....
     Alt+0 = F10
     
     
        6. Files structures
        -------------------
              
        This information is not necessary to use SOFT990.
               
                6.1 SOFT990.CNF
                ---------------
               
                - SOFT990 comunication parameters
                - 14 lines of one data (even if TNC not used)
                - in  order :   serial port for TRX,  serial port  for
     TNC,   speed for TNC,  parity for TNC,  data bits for TNC,   stop
     bits for TNC,  latitude, longitude, UTC-PC, code for transceiver,
     filter for SSB,filter for CW, filter for AM, choice for colors.
                - one  line of 10 datas (2 X 5 values - fist value for
     text  (0-15) - second value for background (0-7) :  selection  of
     colors for main screen, digits, modes, highligh, tnc).
                - 3 lines of one data : speed, sound, CW pitch.
               
                6.2 INFO.DAT
                ------------
               
                - literal information for each channel
                - 90 or 99 lines of text (no blank line)
                - do not use , and "
               
                6.3 BAND.DAT
                ------------
               
                - information for automatic mode switching
                - minimum 1 line
                - maximum 50 lines
                - on each line : F1,F2,M where
     
                        . F1 if the lower limit of mode M
                        . F2 is the upper limit of mode M
                        . M is the mode : 
             (0=LSB, 1=USB, 2=CW, 3=AM, 4=FM, 5=RRTY, 6=PKT)
               
                 - important :  check F1<F2 and describe 0.1 to 30 Mhz
                   
                6.4 RIG.DAT (and RIG.TMP) SOFT990.DAT
                -------------------------------------
          
                 - temporary files - do not erase rig.dat or  any info
     in this file
     
                6.5 DXSPOT.DAT
                --------------
     
        This file is a log of dx-spot from DX-CLUSTER.
     
        This  file  is recalled on each session of SOFT990 - then  the
     last datas from the DX-CLUSTER are not lost.
     
        The content is :
     
                - minimum one line of text
                - maximum 90 lines of text
                - on each line : DX-SPOT in the DX-CLUSTER format
     
                6.6 MEMORIES FILE (BEACONHF.MEM BEACON28.MEM)
                ---------------------------------------------
     
        When you save memories (from the "MENU") SOFT990 create a file
     with the name of your choice and extension .mem as default.
     
        The  content  for  each line is 13 datas  separated  by  comas
     (, or ;) in this order :
     
                - frequency in mhz
                - clarifier value in khz
                - status for tx clar
                - status for rx clar
                - status for +RPT
                - status for -RPT
                - status for REV-RTTY or FM-PKT
                - status for "SCAN" (0 include 1 skip - except FT-920)
                - status for "HIDE" (2 unhide 1 hide)
                - not used
                - status for mode (same format as band.dat)
                - status for filter (0>2.4  1>2.0 / 2>500 / 3>250)
                - channel information
                
        Change this file with care.
     
        BEACONHF.MEM and BEACON28.MEM are two files with HF beacons.
     
        The CSV format match the file format.
     
                6.7 TNC.OUT
                -----------
     
        TNC.OUT is created by SOFT990 when you download data from tnc.
     When you open SOFT990 the soft erase the old file.
     
                6.8 PREFIX.DAT
                --------------
     
        Datas for DXCC information :  all 329 DXCC countries - all ITU
     allocations.  Information  from ARRL Antenna Book,  cahiers du DX
     (LNDX) and by courtesy of N3EQF :  Log-EQF software (c). Download
     the Log-EQF software at http://www.itis.net/eqf.
     
        Do not edit this file.
     
                6.9 *.BCL
                ---------
     
        Datas for the broadcast listening module.
     
        This a text file ; the content is for each line :
     
                - Frequency,Mode,Time,Country,Info
     
        The number of lines is not limited.
     
        Each field is separated by comas (, or ;).
     
                        . Frequency in Mhz
                        . Mode as follow LSB USB CW AM FM RTTY PKT
                        . Time as follw 0000
                        . Country
                        . Info
     
        It is easy to create this file with a spreadsheet (EXCEL) then
     to save it in the "CSV" format.
     
        BCL.BIN  is a random access file used by the software to store
     current information.
     
        The content of the ZIP file is :
     
        File :          Schedule for :          Credit to :
     
        ENGLISH.BCL(*)  English                 BENELUX-DX Club
        FRENCH.BCL      French                  BENELUX-DX Club
        SPANISH.BCL     Spannish                BENELUX-DX Club
        GERMAN.BCL      German                  BENELUX-DX Club
        
        (*) by default
     
        Note :
     
        BENELUX-DX Club :
        Cees van Oudheusden (CJO) - Editor
        http://promet12.cineca.it/htdx/swls/bdxc.html
     
        
                6.10 Log.out and Log.txt
                ------------------------
     
        Log.out  is  a  text file to print with  the  most  importants
     fields of the Logbook.
     
        Log.txt  is a text file with all fields of the Logbook separa-
     ted by coma's (CSV format).  The date format is mm/jj/aaaa.  This
     file  is  very easy to read with Excel.  The headline  gives  the
     field order.
     
                6.11 EXECUTABLE FILES
                ---------------------
     
        All the .EXE file must be present on the directory.
     
        TERMINAL.EXE is the file for the terminal function.
        LOGBOOK.EXE is the file for the Logbook function.
        BCL.EXE is the file for the broadcast listening function
        BCL-R12.EXE is a limited version of broadcast listening module
     BCL.EXE for FT-990 (ROM 1.2)
        FUNCTION.EXE run functions (menu)
        INIT.EXE sets constant
        PANEL.EXE starts the panel command
        ANALYSE.EXE is the file for spectrum analysis
     
        TERMINAL ANALYSE BCL BCL-R12 PANEL FUNCTION and LOGBOOK can be
     used alone.
     
        BRUN45.EXE is the runtime compiler for QuickBasic 4.5 from Mi-
     crosoft (tm). This file is needed to run the soft.
     
     
                6.12 SOFT990.LOG
                ----------------
     
        This file will be created if you use the logbook function.
     
        The  content is the logging information with the Log-EQF  for-
     mat.
     
     
                6.13 SOFT990.PIF MS-DOS.PIF
                ---------------------------
     
        SOFT990.PIF  helps you to configure WINDOWS 95 for the Softwa-
     re ;  do  not use with WINDOWS 3.1.  If the software doesn't  run
     properly with WINDOWS 95 set parameters with a rigth clic.
     
        MS-DOS.PIF helps you to run MS-DOS real mode.
     
                7. History (4...)
                -----------------
                
                - fixed bugs in logbook (4.01)
                - fixed bug when calling LOGBOOK SOFT990.LOG
                - error in french doc (4.03)
                - change of cursor in TNC (4.04)
                - cursor error (4.05 4.06)
                - optimisation for FT-890 (4.07)
                - correction for FT-890 (4.08)
                - add broadcast listening module (4.08)
                - add pop up menu (4.09)        
                - correction in "" (4.10)
                - extension .mem for memory file and comas (4.10)
                - add sort function in bcl (4.10)
                - add COM3 and COM4 (4.11)
                - add shortcut (4.12)
                - add ANALYSE (4.12)
                - graphic band scope (4.13 4.14)
                - minor correction (4.15)
                - add possibility to scan in BCL (4.16) 
                - add a command to smooth the spectrum (4.16)
                - automatic refresh of spectrum in monitoring (4.16)
                - add the EDIT function in BCL module (4.17)
                - change logic of F8 (BCL module) (4.18)
                - add a special timing error routine (4.19 4.20)
                - logbook : change on F5 key (4.21)
                - dx-spot filtering (4.22)
                - dualwatch (4.23)
                - quick memories (4.23)
                - CLEAR function (4.24)         
                - quick memories & BCL (4.25)
                - adding file *.bcl (4.26)
                - BCL : adding KEYWORD capability in scanning( 4.26)
                - adding features to the [V]FO > M function (4.27)
                - signal analysis (4.27)
                - change in F2 F3 keys (monitoring) (4.28)
                - scanning time (BCL) (4.28)
                - BCL.BIN format (4.29)
                - reverse CW (4.30)
                - sub-menu for mode (4.30)
                - running with FT-990/ROM1.2 (4.30)
                - <Espace> to resume scanning (4.33)
                - updated for FT-920 (4.34 4.35)
                - V/S-db meter readout (4.36)
                - add FT1000MP (4.37 4.38)
                - log export utility (4.39)
                - FT-1000D added (4.40)
                - FT-890/840/900 : Tuner bug fixed (4.41)
                - graphic tuning (4.42)
                - alternative Alt+i shortcuts (4.43)
                - filter report (890/900/840) (4.44)
                - filter selection 1000MP (4.45)
                - V conversion (4.46)
     
                         ----------------
               
                                                  
                  F6DEX - 29 Mar 1998
               
                  Laurent Labourie
                  9 rue de la reine Astrid
                  59700 Marcq en Baroeul
               
                  France
               
                  e-mail : 101713.3444@compuserve.com                               
               